| SERVO CONTROLLED VOLTAGE STABILIZERS ARE AVAILABLE IN FOUR MODELS |
- PS analog meter
- DPM digital meter
- DPS digital control
- DCM DC motor control for high speed of correction
|
| CAPACITIES : | 1) 0.5 KVA to 40 KVA I PH | | | 2) 1.5 KVA to 200 KVA 3 PH | | | | | SPECIFICATIONS : | | | Input Voltage Range | 300 V – 460 V AC 50 Hz 3 PH | | Other Input Ranges | 245 V- 460 V AC 3Ph | | 340 V- 460 V AC 3Ph | | 360 V- 460 V AC 3Ph | | other ranges as per customer requirement | | Output Voltage | 380 V / 400 V/ 415 V AC 3Ph 50 Hz | | System | Unbalanced 4 Wire : R Y B N | | Connections | Star | |  | |
| |
| Operating Frequency | 47 Hz to 53 Hz | | Output Voltage Adjustable | 380 V to 415 V AC in 3Ph | | 220 V to 240 V AC in 1Ph | | Output Voltage Regulation | ± 1% | | Over Load Capacity | 120% | | Correction Rate | 15 V / 20 V / 35 V / Sec-1Ph | | 25 V / 35 V / 60 V / Sec-3Ph | | 110V/Sec for D.C. Motor controlled | | Waveform Distortion | Nil | | Output Waveform | True Reproduction of Input | | Insulation | Class 'B' | | Short CKT Period & percentage | 300 % for 250 m.sec. | | Normal Operating Temperature | 0ºC to 45ºC | | Climatic Conditions | 90 % RH.Max.Non-Condensing at 35º C | | Mode of System | Fully Automatic / Manual | System Construction | AS PER IS : 9815 of 1994 | |
| |
| STANDARD PROTECTIONS |
- Low voltage protection
- High Voltage protection
- Overload Protected with MCB / MCCB
- Single Phasing Preventer
|
| PANEL INDICATIONS |
| |
Input | – ON | Output | – ON | Input | – Low | Input | – High | Output | – Cut-off | |
| |
| PANEL METERS |
- Volt Meter With Selector Switch to read Input/Output Voltages, phase to phase and phase to neutral.
- Ammeter With Selector Switch (From 15 KVA 3Ph onwards )
|
| OPTIONAL ACCESSORIES IN 3 Ph SYSTEM |
- Input Under / Over Voltage Trip
- Output Under / Over Voltage ALARAM
- Digital Voltmeter / Ammeter
- Frequency Meter (Digital / Analog)
- Frequency Trip High / Low Adjustable (With setting thumb Wheel switch)
- MCB/MCCB For Output
- Dimmer Protection Arrangement
- Phase Reversal Protection
|
| SAILENT FEATURES |
| |
| Quick Response | Quickest response time 10 ms.(half a cycle) | | High Overload capacity | Higher overload capabilities for high starting and regenerative currents repeated frequency in CNC Machines. | | Fast Correction | Fastest rate of correction up to 70 V/sec. | No Hunting, No Oscillations, No Noise Generation | Machine – Wound Variable Auto Transformer, with special Carbon Brush to minimize carbon deposit and for smooth commutation. | |
| |
| ENERGY SAVINGS |
-
Better efficiency of 98% achieved by use of prime grade Lamination. -
Electrolytic copper wires of 99.99% purity. -
Special designed transformers to minimize losses. -
Also, Special sensing circuit to ensure constant Output Voltage even with distorted input from D.G. set. Conforms to stringent Defence specifications. Tropicalised design |